3.7 How to install the device on the silo
3.7.1 How to install a device with a flange connection
Equipment needed:
•
Device
•
Gasket (not supplied)
•
Nuts and bolts (not supplied)
•
Wrench (not supplied)
Figure 3-7: General installation recommendations
1
The level transmitter can continue to measure to the bottom of the silo if you tilt the device as shown in the illustration
(a 2
°
slanted flange option is available for all antennas)
2
We recommend that you do an empty spectrum recording if there are too many obstacles in the radar beam. For more
data, refer to
How to make a filter to remove radar signal interference
on page 68.
3
Conical silo bottoms. For fine adjustment of the device, refer to
How to measure correctly in silos with curved or conical
bottoms
on page 69.
4
Beam radius (DN80 horn antenna): increments of 90 mm/m or 1.1
¨
/ft (5
°
)
Beam radius (DN100 horn antenna or DN80 Drop antenna): increments of 70 mm/m or 0.83
¨
/ft (4
°
)
Beam radius (DN150 horn antenna): increments of 52.5 mm/m or 0.63
¨
/ft (3
°
)
Beam radius (DN150 Drop antenna or DN200 horn antenna): increments of 35 mm/m or 0.42
¨
/ft (2
°
)
Requirements for flange connections
Figure 3-8: Flange connection
Summary of Contents for SmartLine RM60
Page 8: ...CONTENTS 8 www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US SMARTLINE RM60 FMCW ...
Page 76: ...6 OPERATION 76 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Page 86: ...7 SERVICE 86 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Page 126: ...10 APPENDIX 126 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Page 127: ...APPENDIX 10 127 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...