DESCRIPTION OF HART INTERFACE
9
113
SMARTLINE® RM60 (FMCW)
www.honeywell.com/ps
34-VF-25-31 iss.4 GLO December 15 US
Informational (Warning)
Upper Current output1 has saturated
Rd
/ Upper Current output2 has
saturated
Rd
/ Lower Current output1 has saturated
Rd
/ Lower
Current output2 has saturated
Rd
/ Measurement Old / Measurement
Tank Overfill
Rd
/ Measurement Tank Bottom
Rd
/ Measurement
Terminated
Rd
Process variables
Level
Rd
/ Distance
Rd
/ Reflection
Rd
Primary Output
Primary Function
Rd
/ Distance I1
Rd
/ %Distance
Rd
Secondary Output
Secondary Function
Rd
/ Level I2
Rd
/ %Level
Rd
Calibration Management
Define Test...
Enter Test Data...
Calibration Status...
Calibration History...
Methods
Access Rights
Supervisor / Service
Save Parameters
Diagnostics and Test
Internal Test / Set Output1 / Set Output2
Calibrate
Output1 Lower / Output1 Upper / Output2 Lower / Output2 Upper
Tables
Volume/Mass Table / Linearisation Table / Delete Tables
Empty Spectrum Recording
Reset
Customer Reset / Factory Reset / Device Restart
Summary of Contents for SmartLine RM60
Page 8: ...CONTENTS 8 www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US SMARTLINE RM60 FMCW ...
Page 76: ...6 OPERATION 76 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Page 86: ...7 SERVICE 86 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Page 126: ...10 APPENDIX 126 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...
Page 127: ...APPENDIX 10 127 SMARTLINE RM60 FMCW www honeywell com ps 34 VF 25 31 iss 4 GLO December 15 US ...