72
Encoder and Device Configuration
Figure 5-10
Board Setup View
1.
Select the
Board Setup
tab.
2.
Select from six PTZ dome protocols preconfigured for the dome you have connected
to the encoder. Each PTZ dome has specific baud rate, stop bit, and parity settings.
•
Baud Rate settings range from 2400 to 115200.
•
Stop Bits settings range from 1 to 2.
•
Parity Bits settings range from None, Odd, Even.
Note
For the PTZ dome and the HNVE1 to be able to communicate, the PTZ switch
settings on the PTZ dome and the HNVE1 encoder must be the same. See
Configuring a PTZ Dome
on page
62
for more information about PTZ
switches.
The encoder provides the option of six protocols. The preconfigured values of the baud
rate, stop bit, and parity for each protocol are listed in this table:
Table 5-7
PTZ Configuration Settings
Protocol
Baud Rate
Stop Bit
Parity
Pelco P
4800
1
None
Pelco D
2400
1
None
Diamond
9600
1
Even
IntelliBus
TM
38400
2
None
VCL
9600
2
None
MAXPRO-Net
9600
2
Even