EXPERION MX RAE STATION LAYOUT
6510020335
82
3.
Click
OK
.
When a new recipe is selected all recipe setpoints stored in the database are immediately
loaded as target values.
If the Supervisory loops (Controlled Variables such as Reel Weight and Reel Moisture) are
in control, speed, steam, and stock flow moves immediately to achieve the new CV
setpoints.
For a MANUAL grade change, you may choose to turn the Supervisory loops OFF, load the
new recipe, place the Manipulated Variables such as Basis Weight Flow in Computer and
ease them up or down until it gets a CV such as Reel Weight close to the standard target,
and then turn the Supervisory control back
ON
.
Color Code
NOTE
User can set the main code and color code as “coupled” and “decoupled”
under engineering settings:
•
When the setting is coupled, the color code will be automatically
selected when you select the main code.
•
When the setting is decoupled, the color code needs be manually
selected.
To select a
color code
, use the following instructions:
1.
Navigate to
Simple Recipe Change
page.
2.
On the
Select Recipe Type
field, click on the drop-down to select the desired color
code.
Summary of Contents for Experion MX
Page 1: ...Experion MX RELEASE 702 1 Operators Guide 6510020335 Rev 02 May 2019 ...
Page 7: ...6510020335 7 8 NOTICES 168 ...
Page 20: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 20 Fig 15 Cable End Voltage Zones ...
Page 21: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 21 Fig 16 Distant End Voltage Zones ...
Page 124: ...PROCESS INFORMATION DISPLAYS 6510020335 124 Fig 105 Profile Display ...
Page 159: ...PROCESS INFORMATION DISPLAYS 6510020335 159 Fig 148 Precision Platform 4000 01 Scanner ...
Page 160: ...PROCESS INFORMATION DISPLAYS 6510020335 160 Fig 149 Precision Platform 4000 20 21 Scanner ...