SCANNER SAFETY AND LOCAL CONTROLS
6510020335
46
Fig. 42.
Thermal Switch
Purpose:
These devices are intended to protect equipment and sensors only in case of unintended
extreme conditions. Tripping of these devices indicates abnormal behavior. Diagnose and
adjust the operation of the scanner.
The cable end temperature limit switch disables power to the cabinet subsystems in case
of temperatures exceeding 65 °C (149 °F) at the switch location.
The head temperature reporting causes sheet guide and air wipe heaters to be disabled at
a temperature of 55 °C (131 °F), and commands heads offsheet.
The thermal switch and temperature reporting of the air wipe heater
r body allows power to be disconnected in case of no or low air flow through heater.
2.3.3
Radiation Safety Features
2.3.3.1 Radiation safety warning indicators, red and green lights
Description:
Red and green radiation shutter status indicators are mounted to the head (see Figure 43),
and integrated into the user panel on each end of the scanner (see Figure 45). A radiation
warning label is in close proximity to these indicators.
Summary of Contents for Experion MX
Page 1: ...Experion MX RELEASE 702 1 Operators Guide 6510020335 Rev 02 May 2019 ...
Page 7: ...6510020335 7 8 NOTICES 168 ...
Page 20: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 20 Fig 15 Cable End Voltage Zones ...
Page 21: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 21 Fig 16 Distant End Voltage Zones ...
Page 124: ...PROCESS INFORMATION DISPLAYS 6510020335 124 Fig 105 Profile Display ...
Page 159: ...PROCESS INFORMATION DISPLAYS 6510020335 159 Fig 148 Precision Platform 4000 01 Scanner ...
Page 160: ...PROCESS INFORMATION DISPLAYS 6510020335 160 Fig 149 Precision Platform 4000 20 21 Scanner ...