Maintenance
77
Always leave at least one battery connected to the DL230 (to
X5 or X6) when changing batteries. This way, the DL230 will
continue to work whilst the batteries are being changed.
CAUTION!
Reduced battery power!
The simultaneous use of an old and a new battery
considerably reduces battery power.
Therefore:
– When using two batteries always exchange both at the
same time.
Ill.: 20
1. If the external power supply is
connected, then disconnect it.
2. The grey covering strips on both
the right and left-hand side of the
cover are pressed out-wards at
the small groove (Ill.: 20 1 ). This
means that the screws on the
cover become visible.
3. Loosen the four screws
(Ill.: 20 2 ) with which the
housing is connected.
4. Open the cover of the DL230 by
pushing down on it.
Ill.: 21
5. Loosen the screw on the battery
: 1 and pull out the
mounting element for the battery 2 .
The element fits very snugly in the
guides.
6. Mark the old battery using e.g. a felt-
tipped pen or stickers.
7. Choose the free
CPU Power
con-
nection on the board to connect to
the new battery (
: X5 or X6).
8. Place the new battery onto the base
of one of the three locations
provided for it (
: 3 ).
1
2
1
1
3
2
Summary of Contents for DL230
Page 6: ......
Page 98: ...98 Appendix 9 3 EC Declaration of Conformity ...
Page 99: ...Appendix 99 9 4 ATEX Type Examination Certificate 9 4 1 Associated apparatus for Zone 0 1 ...
Page 100: ...100 Appendix ...
Page 101: ...Appendix 101 ...
Page 102: ...102 Appendix ...
Page 103: ...Appendix 103 ...
Page 104: ...104 Appendix ...