Assembly, Connection and Putting into Operation
39
5.2.2
Sealing the input terminals
After connecting to the meter as per chapter 5.2.1 the respective DE1 to
DE4 input terminal must be sealed for official calibration measurements.
For this purpose, terminal covers are provided in the bag of accessories. If
required, these should be screwed over the connected terminals and an
adhesive seal should then be bonded to the fastening screw (see chapter
5.3.2).
5.2.3
Connecting the power supply
5.2.3.1 Power supply for the DL230 with integrated power supply
unit
DANGER!
Danger to life from electrical current!
Touching live parts poses an imminent danger to life.
Therefore:
– Works on the electrical components of the device, i.e.
the connection of the power supply unit, should solely be
carried out by qualified electricians.
– When performing all works to the electrical system,
switch off the power, secure it against an accidental
restart and check to ensure that the voltage has been
cut.
– Keep moisture from live parts away. This could lead to
short-circuit.
The power supply unit to connect the 230 V~ power supply, is
in-built into the base of the DL230.
III. 9
1. Switch off the supply voltage and secure
it against an accidental restart!
2. Connect the 230V~ supply voltage to the
terminal block (
1 ) of the power supply.
Terminal "PE" is the connection for the
protective conductor (protective
earthing).
1
Summary of Contents for DL230
Page 6: ......
Page 98: ...98 Appendix 9 3 EC Declaration of Conformity ...
Page 99: ...Appendix 99 9 4 ATEX Type Examination Certificate 9 4 1 Associated apparatus for Zone 0 1 ...
Page 100: ...100 Appendix ...
Page 101: ...Appendix 101 ...
Page 102: ...102 Appendix ...
Page 103: ...Appendix 103 ...
Page 104: ...104 Appendix ...