Assembly, Connection and Putting into Operation
45
– On successful detection the DL230 displays the label "Vo1" on the me-
ter reading of the meter:
Serv.
Input 1
Vo1
Unlike the "Auto Detect" function, you can also select the connected
encoder type directly under "Md.I1".
Serv.
Input 1
Parameter settings
Md.I1
The following encoder types can be selected:
Md.E1
Description
Enc.Namur a
Encoder with Namur a protocol
Enc.SCR EDIS
Encoder SCR with EDIS95 protocol
Enc.SCR OBIS
Encoder SCR with OBIS05 protocol
Enc.SCR+EDIS
Encoder SCR+ with EDIS95 protocol
Enc.SCR+OBIS
Encoder SCR+ with OBIS05 protocol
Enc.Nam. a-b
Encoder with Namur a and b protocols
The same process can be used for input 2.
With the parameter "
EZyk
" you can set for both encoder inputs at what in-
tervals the encoder is read out. Default is 900 seconds (15 minutes).
Changing this parameter has a significant impact on battery life !
"EZyk" can be found in the display under the path:
Serv.
Device settings
Measurement
5.3.1.4 Adjusting meter readings
To control the measuring of volumes, the meters (V1 to V4) of the DL230
can be adjusted to the same respective value as the meters connected
when the calibration or administrator lock is open (with an entry in the PTB
log).
– Open the calibration lock or the administration lock
– Move the cursor to the "Serv." register and to the value "V1", "V2", "V3"
or "V4":
Serv.
Input 1
V1
Serv.
Input 2
V2
Serv.
Input 3
V3
Serv.
Input 4
V4
– Press the ENTER
button. One of the value's digits flashes.
– Move the cursor to the digits using the
or
arrow keys and update
them using the
or
arrow keys.
Summary of Contents for DL230
Page 6: ......
Page 98: ...98 Appendix 9 3 EC Declaration of Conformity ...
Page 99: ...Appendix 99 9 4 ATEX Type Examination Certificate 9 4 1 Associated apparatus for Zone 0 1 ...
Page 100: ...100 Appendix ...
Page 101: ...Appendix 101 ...
Page 102: ...102 Appendix ...
Page 103: ...Appendix 103 ...
Page 104: ...104 Appendix ...