• CAM HEIGHT
Replace the cam if the cam height is lower than the service
limit.
• CAM PULLEY SHAFT O.D.
• CAM PULLEY I.D.
• VALVE SPRING FREE LENGTH
Measure the free length of the valve spring.
Replace the springs if they are shorter than the service limit.
Standard
Service limit
22.097 mm (0.8700 in)
21.797 mm (0.8581 in)
Standard
Service limit
3.990 ~ 4.000 mm
(0.1571 ~ 0.1575 in)
3.950 mm
(0.1555 in)
Standard
Service limit
4.020 ~ 4.050 mm
(0.1583 ~ 0.1595 in)
4.100 mm
(0.1614 in)
Standard
Service limit
20.66 mm (0.8134 in)
20.00 mm (0.7874 in)