85
FL Group
:
Fault Protection Parameters
(
total 22
)
Code
Name
Setting Scope
Min Unit
Defaulted
Value
Address
Chang
e
FL.00
Motor overload protection
0
:
Disable
1
:
Common motor
(
low
speed compensation
)
2
:
Varible frequency
motor
(
No low speed
compensation
)
1
2
1100H
×
FL.01
Motor overload protection
factor
20.0
~
110%
0.1%
100.0%
1101H
×
FL.02
stall overvolage
0
:
Disable
1
:
Enable
1
1
1102H
×
FL.03
Stall overvoltage point
110.0
~
150.0%
0.1%
140.0%
1103H
×
FL.04~
FL.06
Reserved
-
-
-
1104H~
1106H
*
FL.07
Automatic current limit
threshold
20.0
~
200.0%
0.1%
160.0%
1107H
×
FL.08
Reserved
-
-
-
1108H
*
FL.09
Action mode of autocurrent
limit
0
:
Constant speed invalid
1
:
Constant speed
effective
2
:
Automatic current limit
valid in run state 1
3
:
Reserved
4
:
Reserved
5: Automatic current limit
valid in run state 2
1
5
1109H
×
FL.10~
FL.13
Reserved
-
-
-
110AH~
110DH
*
FL.14
Fault type of the first two
time
0
:
No abnormal records
1
:
Overcurrent run at
acceleration (F.oC1)
2
:
Overcurrent run at
deceleration (F.oC2)
3
:
Overcurrent run at
constant speed(F.oC3)
1
0
110EH
*
FL.15
Fault type of the
previoustime
1
0
110EH
*
FL.16
Fault type of the lasttime
1
0
110FH
*