78
F9 GROUP
:
Enhanced Funtion Parameters
(
total 51
)
Code
Name
Setting Scope
Min Unit
Defaulted
Value
Address Change
F9.15
Positvie or negative logic of
terminal
LED Units
:
Bit0
~
Bit3: X1
~
X4
LED Tens
:
Bit0
:
X5
Bit1
~
Bit3: Reserved
LED Hundreds
:
Bit0
~
Bit3: Reserved,
Reserved,Y1, Reserved
LED Thousands
:
Reserved
BIT Settings:
0: Valid when X and
common connected,
disconnect is invalid;
1: Invalid when X and
common connected,
disconnect is valid;
1
000
90FH
○
F9.16~
F9.17
Reserved
-
-
-
910H~
911H
*
F9.18
Digital auxiliary reference
control
LED Units
:
Storage
control
0
:
power failure storage
auxiliary frequency
1
:
power failure no
storage auxiliary
frequency
LED Tens
:
Halt
frequency control
0
:
Maintain auxiliary
frequency after halt
1
:
Reset frequency after
halt
LED Hundreds
:
Auxiliary given
superposition polarity
0
:
Positive polarity
1
:
Negative polarity
1
000
912H
○
F9.19~
F9.21
Reserved
-
-
-
913H~
915H
*
F9.22
Cooling fan
0
:
automatic run
1
:
run when power on
1
0
916H
×
F9.23~
F9.29
Reserved
-
-
-
917H~
91DH
*
F9.30
Conditions of restart after
power failure
0
:
invalid
1
:
valid
1
0
91EH
×
F9.31~
F9.33
Reserved
-
-
-
91FH~
921H
*
F9.34
Terminal filter time
0.5~100.0ms
0.1 ms
7.5 ms
922H
×