69
9.
Parameter profiles
“○”
:
Indicate the set value of the parameter can be changed when the inverter is in stop
status or running status.
“×”
:
Indicate the set value of the parameter cannot be changed when the inverter is in
running status.
“*”
:
It represents the value of this parameter is the actually measured value and cannot be
changed.
“-”: It indicates that the parameter is "Factory default parameter" set only by the
manufacturer and forbidden for users to change.
“Address” is the address of MODBUS protocol register
。
F0 Group
:
Basic Function Parameters
(
total 15 items
)
Code
Name
Setting Scope
Min Unit
Defaulted
Value
Address Change
F0.00
Command channel
0:Keypad command channel
1:Termminal control
2:Serial communication port
control
1
0
000H
○
F0.01
Reserved
-
-
-
001H
*
F0.02
Frequency source setting
0
:
Digital setting 1
(Up/Down key)
1
:
Digital setting 2
(Terminal UP/DN )
2: Digital setting3
Serial communication port
3
:
Reserved
4
:
AI setting
5
:
Reserved
6
:
Keypad potentionmeter
setting
1
0
002H
○
F0.03
Auxiliaryreference
frequency
0
:
Invalid
1
:
Digital setting,up/down
key
(
Initial value F0.05
)
2
:
Digital setting
,
terminal
UP/DN
(
Initial value F0.05
)
3
:
Serial port setting
(
Initial value F0.05
)
1
0
003H
○