84
FD Group
:
Professional function parameters 2
(
total 31
)
Code
Name
Setting Scope
Min Unit
Defaulted
Value
Address Change
FD.03
Stage 2 setting
LED Units
:
0
:
Select mulit frequency
2(F8.01)
1
:
Frequnecy depends on
thefunction code of F0.02
LEDTens
:
0
:
Forward
1
:
Reverse
2
:
Subject to run
command
1
00
D03H
○
FD.04
Stage 2 run time
0.0~6500 s(min)
0.1
20.0s
D04H
○
FD.05
Stage 3 setting
LEDUnits
:
0
:
Select mulit frequency
3(F8.02)
1
:
Frequnecy depends on
thefunction code of F0.02
LEDTens
:
0
:
Forward
1
:
Reverse
2
:
Subject to run
command
1
00
D05H
○
FD.06
Stage 3 run time
0.0~6500 s(min)
0.1
20.0s
D06H
○
FD.07
Stage 4 setting
LEDUnits
:
0
:
Select mulit frequency
4(F8.03)
1
:
Frequnecy depends on
thefunction code of F0.02
LEDTens
:
0
:
Forward
1
:
Reverse
2
:
Subject to run
command
1
00
D07H
○
FD.08
Stage 4 run time
0.0~6500 s(min)
0.1
20.0s
D08H
○
FD.09~
FD.30
Reserved
-
-
-
D09H~
D1EH
*