6 Optional functions
189
SMGB0087 rev.0 - 12/2013
6
Element
Optional function
Individual
setting
Settings
Setting conditions
Description
J9
Not available
–
–
Not available (Use
as 00 conditions)
PC-ARF only
JA
Not available
–
–
Not available (Use
as 00 conditions)
PC-ARF only
Jb
Not available
–
–
Not available (Use
as 00 conditions)
PC-ARF only
K1
Not available
X
–
Not available (Use
as 00 conditions)
PC-ARF only
K2
Not available
X
–
Not available (Use
as 00 conditions)
PC-ARF only
K3
Not available
X
–
Not available (Use
as 00 conditions)
PC-ARF only
K4
Not available
–
–
Not available (Use
as 00 conditions)
PC-ARF only
K5
Human sensor
detection level
–
00
Standard
PC-ARF only
01
High
PC-ARF only
02
Low
PC-ARF only
O: allows for individual setting.
X: the setting is made for all outdoor units.
–: not used.
*1 Setting “02” is not available on all indoor units.
*2 On RPI units: 00 Increases speed 1 (standard), 01 Increases speed 2 (high static pressure), 02 Standard speed (low
static pressure).
*3 00 standard (7-step operation); 01 draft prevention (cannot be set below two steps); 02 High ceilings (cannot be set
above two steps).
*4 In case that the set temperature is changed and kept within the set time at “F4”, the temperature is automatically
changed to “F5” and “F6”. In case that the set temperature is out of range at “F5” and “F6”, it is applied within upper and
lower limit for the set temperature.
*
5 Operation is stopped by pressing the run/stop switch for 3 seconds.
*
6 When the unit is restared by the remote control switch, the temperature automatically changes to the setting temperature
of “F5” or “F6”.
*7 The sensor value at “C8” will be indicated. When the thermistor for remote control switch is used, the average value of
the thermistor for remote control switch and the thermistor for indoor inlet will be indicated.
*8: Applicable to fan, cooling and dry operation modes.
*9: Applicable to heating operation mode.
N O T E
• Makes the changes to the optional settings at least three minutes following start-up.
• On modifying the ”CF” (air outlet louver angle change) setting, restore the power supply or allow the automatic louver
to make a full cycle in automatic mode to apply the optional setting.
• The optional function settings are different depending on the indoor or outdoor units. Check that the unit has the op-
tional setting.
• The above optional functions with “X” mark at the individual setting can change the condition only when “All Rooms”
is set.
Summary of Contents for RAS-(2-6)HVNP1(E)
Page 2: ......
Page 4: ... II ...
Page 28: ......
Page 134: ...4 Electrical wiring 120 SMGB0087 rev 0 12 2013 4 7 3 RAS 3HVNP1E 1 230V 50Hz XEK01261_0 ...
Page 136: ...4 Electrical wiring 122 SMGB0087 rev 0 12 2013 4 7 4 RAS 4 6 HVNP1E 1 230V 50Hz XEK01262_1 ...
Page 138: ...4 Electrical wiring 124 SMGB0087 rev 0 12 2013 4 7 6 RAS 4 6 HNP1E 3N 400V 50Hz XEK01263_2 ...
Page 140: ...4 Electrical wiring 126 SMGB0087 rev 0 12 2013 4 7 7 RAS 4 6 HVNC1E 1 230V 50Hz XEK01264_4 ...
Page 142: ...4 Electrical wiring 128 SMGB0087 rev 0 12 2013 4 7 8 RAS 4 6 HNC1E 3N 400V 50Hz XEK01265_4 ...
Page 146: ...4 Electrical wiring 132 SMGB0087 rev 0 12 2013 4 7 12 RAS 12HN P C 3N 400V 50Hz 7T146440 ...
Page 148: ......
Page 204: ......
Page 220: ......
Page 332: ......
Page 353: ...9 Spare parts 339 SMGB0087 rev 0 12 2013 9 RAS 8 10 HNCE Spare Parts Document EPN 201211D ...
Page 362: ......
Page 484: ......
Page 496: ......
Page 497: ......