ENGLISH
Element
Optional function
Individual
setting
Settings
Setting conditions
Description
L3
Operation of the louvres
in energy-saving thermo
OFF (Cooling / Dry
mode)
O
00
Direct air blow Low (factory setting)
Power save must be ON in order to
use this function (L5 must be set to
01).
This function is used to establish
louvre swinging operation ranging
from continuous swing to static
operation.
Low: Continuous louvre swing
Medium: Louvre swing with
intermittent stops for 20/40 seconds
High: Louvre stopped at full opening
position, according to the setting of
CF.
01
Direct air blow Medium
02
Direct air blow High
03
Disabled
L4
Fan acceleration in
energy-saving thermo
OFF (Cooling mode)
O
00
Function disabled
(factory setting)
This function increases fan speed
by one step to prevent the loss of
comfort due to the forced thermo
OFF for energy saving during cooling
operation.
01
Function enabled
L5
Louvre swing operation
during energy-saving
forced thermo OFF
O
00
Function disabled
(factory setting)
This function is used to enabled the
setting of function L3.
01
Function enabled
L6
Not used
-
00
-
Use at 00 conditions
01
L7
Not available
–
“- -”
permanent –
–
L8
Not used
-
00
-
Use at 00 conditions
01
L9
Not used
-
00
-
Use at 00 conditions
01
LA
Not used
-
00
-
Use at 00 conditions
01
Lb
Not used
-
00
-
Use at 00 conditions
01
P1
Setting temperature in
0.5 ºC steps
X
00
Enabled (0.5 °C steps)
(factory setting)
This function is used to define
whether setting temperature is
adjusted in 0.5 ºC steps (when set
to “00”) or in 1 ºC steps (when set to
“01”).
This setting also determines whether
the resolution of temperature
differential of the thermistor is 0.5 ºC
(when set to “00”) or 1 ºC (when set
to “01”).
01
Disabled (1 °C steps)
P2
Not used
-
00
-
Use at 00 conditions
01
P3
Temperature sensor
displayed
X
00
Inlet air thermistor (Tin)
This function is used to select the
thermistor whose temperature is
shown when function P4 is set to 01.
01
Outdoor air thermistor (Tout)
02
Remote controller thermistor (RCS)
03
Remote sensor (THM4)
P4
Display of sensor
temperature
X
00
Hidden
This function is used to display the
temperature of the sensor selected
with function P3.
01
Shown
P5
Display of setting
temperature when
operation mode is Fan
X
00
Shown
This function is used to hide the
display of setting temperature during
operation in fan mode.
01
Hidden
TEST RUN MENU
PMML0496 rev.1 - 12/2020
21