Rev. 3.0, 10/02, page 71 of 686
4.6
Trap Instruction
Trap instruction exception handling starts when a TRAPA instruction is executed. Trap instruction
exception handling can be executed at all times in the program execution state.
The trap instruction exception handling is as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended control
register (EXR) are saved in the stack.
2. The interrupt mask bit is updated and the T bit is cleared.
3. A vector address corresponding to the interrupt source is generated, the start address is loaded
from the vector table to the PC, and program execution starts from that address.
The TRAPA instruction fetches a start address from a vector table entry corresponding to a vector
number from 0 to 3, as specified in the instruction code.
Table 4.5 shows the status of CCR and EXR after execution of trap instruction exception handling.
Table 4.5
Status of CCR and EXR after Trap Instruction Exception Handling
CCR
EXR
Interrupt Control Mode
I
UI
I2 to I0
T
0
1
–
–
–
2
1
–
–
0
Legend:
1: Set to 1
0: Cleared to 0
–: Retains value prior to execution.
Summary of Contents for H8S/2215 Series
Page 4: ...Rev 3 0 10 02 page iv of lviii ...
Page 6: ...Rev 3 0 10 02 page vi of lviii ...
Page 28: ...Rev 3 0 10 02 page xxviii of lviii ...
Page 122: ...Rev 3 0 10 02 page 64 of 686 ...
Page 132: ...Rev 3 0 10 02 page 74 of 686 ...
Page 156: ...Rev 3 0 10 02 page 98 of 686 ...
Page 198: ...Rev 3 0 10 02 page 140 of 686 ...
Page 320: ...Rev 3 0 10 02 page 262 of 686 ...
Page 384: ...Rev 3 0 10 02 page 326 of 686 ...
Page 474: ...Rev 3 0 10 02 page 416 of 686 ...
Page 608: ...Rev 3 0 10 02 page 550 of 686 ...
Page 614: ...Rev 3 0 10 02 page 556 of 686 ...
Page 650: ...Rev 3 0 10 02 page 592 of 686 ...
Page 652: ...Rev 3 0 10 02 page 594 of 686 ...
Page 680: ...Rev 3 0 10 02 page 622 of 686 ...
Page 732: ...Rev 3 0 10 02 page 674 of 686 ...
Page 740: ...Rev 3 0 10 02 page 682 of 686 ...