Upgrading a Hitachi Unified Storage 130 system
15–9
Hitachi Unified Storage Hardware Service Guide
3. In the next page:
a. Enter the following default IP address in the Specific IP Address or
Array Name fields for each storage system management port.
Controller 0: type 192.168.0.16
Controller 1: type 192.168.0.17
b. In the Using Ports area, select whether the ports are secure,
nonsecure, or both.
c. Click Next.
4. In the next page:
a. Enter a storage system name in the Array Name field.
b. Click Next.
5. Click Finish.
6. At the Arrays page, confirm that the status of the Hitachi Unified Storage
system is Normal.
Locking extra-cost options
If one or more extra-cost (or “priced”) options other than Dynamic
Provisioning and Data Retention Utility are used with the CBSL or CBSS,
uninstall (or “lock”) the option prior to performing the upgrade. This
procedure requires you to use Hitachi Storage Navigator Modular 2 and the
key code or key file supplied with the option.
If the CBSL or CBSS does not have priced options, skip this procedure and
Registering the Hitachi Unified Storage system on page 15-7
.
1. Record the settings of the option for future reference.
2. At the Hitachi Storage Navigator Modular 2 Arrays page, check the
storage system that has the extra-cost option.
3. Press the Ctrl, Shift, and E keys at the same time to switch Hitachi
Storage Navigator Modular 2 to Maintenance Mode. Confirm that
Maintenance Mode appears next to Operation Mode on the Arrays
page (see
NOTE: If your management console is directly connected to a
maintenance port, enter the default IP address just for that port
(Controller 0 = 10.0.0.16, Controller 1 = 10.0.0.17).
NOTE: If Maintenance Mode does not appear next to Operation Mode,
click a blank area in the Arrays page (away from GUI components such as
buttons and check boxes), and then press the Ctrl, Shift, and E keys at the
same time.
Summary of Contents for CBL
Page 20: ...xx Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS ...
Page 30: ...xxx Hitachi Unified Storage Hardware Service Guide CBL CBLE CBLD DBS DBSD DBL DBLD DBF ...
Page 39: ...xxxix Hitachi Unified Storage Hardware Service Guide Out ...
Page 40: ...xl Hitachi Unified Storage Hardware Service Guide ...
Page 152: ...5 8 Replacing a cache backup battery Hitachi Unified Storage Hardware Service Guide ...
Page 156: ...6 4 Replacing a Fan Module Hitachi Unified Storage Hardware Service Guide ...
Page 180: ...8 16 Adding and replacing controllers Hitachi Unified Storage Hardware Service Guide ...
Page 188: ...9 8 Replacing cache memory Hitachi Unified Storage Hardware Service Guide ...
Page 200: ...11 6 Replacing the Host connector Hitachi Unified Storage Hardware Service Guide ...
Page 204: ...12 4 Replacing the Drive I O Module Hitachi Unified Storage Hardware Service Guide ...
Page 212: ...14 4 Replacing the SAS ENC cable Hitachi Unified Storage Hardware Service Guide ...
Page 274: ...17 14 Troubleshooting Hitachi Unified Storage Hardware Service Guide ...
Page 291: ...1 Hitachi Unified Storage Hardware Service Guide ...