15–18
Upgrading a Hitachi Unified Storage 130 system
Hitachi Unified Storage Hardware Service Guide
The RAID Group/DP Pool/Volume information is stored as a text file that
is named as shown above.
Store this file in a safe place because you will refer to it after you perform
the upgrade.
Shutting down the storage system
After collecting drive serial numbers, a clean power down of the Hitachi
Unified Storage 130 storage system (CBSS or CBSL) from the main power
off switch is required. The clean power down must be performed from the
main Power Off switch on Controller #0 or Controller #1. Do not power
down using the power cables.
1. Confirm the following:
- Do not power off the storage system if the green READY LED on
the front of the Controller Box is blinking quickly (it can remain
blinking up to 50 minutes).
- If the Power Saving option is used, initiate a spin-down, and then
power off the storage system before spin-down completes, the
spin-down may fail. Therefore, wait for spin-down to complete
before powering off the storage system.
Confirm that no RAID Group has a power saving status of Normal
(command monitoring) after executing the spin-down.
If the spin-down fails, perform the spin-down again.
- Confirm that there are no drives whose status is Blocked. If there
are, resolve the block before powering off the storage system.
Summary of Contents for CBL
Page 20: ...xx Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS ...
Page 30: ...xxx Hitachi Unified Storage Hardware Service Guide CBL CBLE CBLD DBS DBSD DBL DBLD DBF ...
Page 39: ...xxxix Hitachi Unified Storage Hardware Service Guide Out ...
Page 40: ...xl Hitachi Unified Storage Hardware Service Guide ...
Page 152: ...5 8 Replacing a cache backup battery Hitachi Unified Storage Hardware Service Guide ...
Page 156: ...6 4 Replacing a Fan Module Hitachi Unified Storage Hardware Service Guide ...
Page 180: ...8 16 Adding and replacing controllers Hitachi Unified Storage Hardware Service Guide ...
Page 188: ...9 8 Replacing cache memory Hitachi Unified Storage Hardware Service Guide ...
Page 200: ...11 6 Replacing the Host connector Hitachi Unified Storage Hardware Service Guide ...
Page 204: ...12 4 Replacing the Drive I O Module Hitachi Unified Storage Hardware Service Guide ...
Page 212: ...14 4 Replacing the SAS ENC cable Hitachi Unified Storage Hardware Service Guide ...
Page 274: ...17 14 Troubleshooting Hitachi Unified Storage Hardware Service Guide ...
Page 291: ...1 Hitachi Unified Storage Hardware Service Guide ...