Verifying component failures
1–5
Hitachi Unified Storage Hardware Service Guide
When a failure is recognized, use the following procedure to recover the
failure.
1. If Storage Navigator Modular 2 is not running, launch a Web browser,
and then start and log in to Storage Navigator Modular 2.
If Storage Navigator Modular 2 is running, in the Explorer pane, click
Arrays, and then return to the Storage Navigator Modular 2 main
window.
2. Using Storage Navigator Modular 2, check the status of the storage
system where the failure occurred.
3. Check the email or SNMP alert that notified you about the failure, or
check the serial number on the label attached on the subsystem where
the failure occurred.
4. In the Storage Navigator Modular 2 Arrays window, check the Status of
the storage system array where the failure occurred.
NOTE: If Storage Navigator Modular 2 does not start, a communication
failure with the Storage Navigator Modular 2 host might have occurred or
the Storage Navigator Modular 2 host might not have started normally. See
Hitachi Storage Navigator Modular 2 does not start on page 17-2
Mail or SNMP text
Serial number label
xxxxxxxxxxxxxxxxxxxx
Hardware serial number:
92012345
xxxxxxxxxxxxxxxxxxxx
Array serial
number labels
Summary of Contents for CBL
Page 20: ...xx Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS ...
Page 30: ...xxx Hitachi Unified Storage Hardware Service Guide CBL CBLE CBLD DBS DBSD DBL DBLD DBF ...
Page 39: ...xxxix Hitachi Unified Storage Hardware Service Guide Out ...
Page 40: ...xl Hitachi Unified Storage Hardware Service Guide ...
Page 152: ...5 8 Replacing a cache backup battery Hitachi Unified Storage Hardware Service Guide ...
Page 156: ...6 4 Replacing a Fan Module Hitachi Unified Storage Hardware Service Guide ...
Page 180: ...8 16 Adding and replacing controllers Hitachi Unified Storage Hardware Service Guide ...
Page 188: ...9 8 Replacing cache memory Hitachi Unified Storage Hardware Service Guide ...
Page 200: ...11 6 Replacing the Host connector Hitachi Unified Storage Hardware Service Guide ...
Page 204: ...12 4 Replacing the Drive I O Module Hitachi Unified Storage Hardware Service Guide ...
Page 212: ...14 4 Replacing the SAS ENC cable Hitachi Unified Storage Hardware Service Guide ...
Page 274: ...17 14 Troubleshooting Hitachi Unified Storage Hardware Service Guide ...
Page 291: ...1 Hitachi Unified Storage Hardware Service Guide ...