15–38
Upgrading a Hitachi Unified Storage 130 system
Hitachi Unified Storage Hardware Service Guide
Registering the Hitachi Unified Storage 150
After upgrading the Hitachi Unified Storage 150, use Hitachi Navigator
Modular 2 to register the storage system
1. Connect the maintenance PC to the storage system and start Hitachi
Storage Navigator Modular 2, and log in.
2. At the Arrays page, check the storage system.
3. Press the Ctrl, Shift, and E keys at the same time to switch to
Maintenance Mode. Confirm that Maintenance Mode appears next to
Operation Mode on the Arrays page.
4. Confirm that the Hitachi Unified Storage 150 appears on the Arrays
page.
5. Click the Remove Array button at the bottom-right side of the Arrays
page.
6. Click Close.
7. When a message tells you that the array was removed successfully, click
Close.
8. Confirm that the Hitachi Unified Storage 150 has been removed from the
Arrays page.
The storage system is now registered following the upgrade.
Completing the upgrade
To complete the upgrade, perform the following procedure.
1. If you configured Hitachi Storage Navigator Modular 2 to send email
alert notifications, change the device model name displayed in the email
alerts. Refer to the Hitachi Unified Storage Hardware Installation and
Configuration Guide and the Hitachi Storage Navigator Modular 2 online
help.
2. If you use SNMP Agent Support Function, change the device model name
displayed in the alerts sent by this application. Refer to the Hitachi
Unified Storage Operations Guide and the Hitachi Storage Navigator
Modular 2 online help.
3. Disconnect the maintenance PC from the Hitachi Unified Storage 150.
4. Attach the front bezel to the Hitachi Unified Storage 150 (see
and replacing the front bezel on page 3-10
5. If you purchased a priced option, contact Hitachi Support for instructions
about installing (or “unlocking”) it for use. You cannot use the license
key of the priced option that was used prior to the upgrade.
6. Reboot the host computer and prepare it for use with the Hitachi Unified
Storage 150.
This completes the procedure for upgrading a Hitachi Unified Storage 130
to a Hitachi Unified Storage 150.
Summary of Contents for CBL
Page 20: ...xx Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS ...
Page 30: ...xxx Hitachi Unified Storage Hardware Service Guide CBL CBLE CBLD DBS DBSD DBL DBLD DBF ...
Page 39: ...xxxix Hitachi Unified Storage Hardware Service Guide Out ...
Page 40: ...xl Hitachi Unified Storage Hardware Service Guide ...
Page 152: ...5 8 Replacing a cache backup battery Hitachi Unified Storage Hardware Service Guide ...
Page 156: ...6 4 Replacing a Fan Module Hitachi Unified Storage Hardware Service Guide ...
Page 180: ...8 16 Adding and replacing controllers Hitachi Unified Storage Hardware Service Guide ...
Page 188: ...9 8 Replacing cache memory Hitachi Unified Storage Hardware Service Guide ...
Page 200: ...11 6 Replacing the Host connector Hitachi Unified Storage Hardware Service Guide ...
Page 204: ...12 4 Replacing the Drive I O Module Hitachi Unified Storage Hardware Service Guide ...
Page 212: ...14 4 Replacing the SAS ENC cable Hitachi Unified Storage Hardware Service Guide ...
Page 274: ...17 14 Troubleshooting Hitachi Unified Storage Hardware Service Guide ...
Page 291: ...1 Hitachi Unified Storage Hardware Service Guide ...