Upgrading a Hitachi Unified Storage 130 system
15–7
Hitachi Unified Storage Hardware Service Guide
Starting Hitachi Storage Navigator Modular 2
Configuration activities associated with the upgrade are performed using
Hitachi Storage Navigator Modular 2. Some activities require you to
configure Hitachi Storage Navigator Modular 2 for Maintenance Mode, while
other procedures are performed in Normal Mode.
To start Hitachi Storage Navigator Modular 2:
1. Connect an Ethernet cross-over cable to the LAN 0 maintenance port on
the rear of the CBSS or CBSL Controller Box. Connect the other end of
the cable to a maintenance PC that has an installed version of Hitachi
Storage Navigator Modular 2.
2. Start Internet Explorer on the maintenance PC, and then start Hitachi
Storage Navigator Modular 2 and log in.
3. Perform a simple trace (see
Collecting trace information on page 3-13
).
This will help you troubleshoot in the unlikely event the firmware
upgrade (described later in this chapter) fails.
4. Remove all Fibre Channel and iSCSI cables from the rear of the CBSL or
CBSS. Leave the other end of the cables connected to their respective
devices.
5. Leave Hitachi Storage Navigator Modular 2 running and proceed to
, below.
Registering the Hitachi Unified Storage system
Use the following procedure to register the Hitachi Unified Storage system
containing the CBSL or CBSS that will be upgraded.
1. In Hitachi Storage Navigator Modular 2, click the Add Array button in
the Arrays screen.
NOTE: Use Internet Explorer because it supports Hitachi Storage
Navigator Modular 2 in Maintenance Mode. Firefox and Chrome do not
support Maintenance Mode.
Summary of Contents for CBL
Page 20: ...xx Hitachi Unified Storage Hardware Service Guide Labels on the CBXSS ...
Page 30: ...xxx Hitachi Unified Storage Hardware Service Guide CBL CBLE CBLD DBS DBSD DBL DBLD DBF ...
Page 39: ...xxxix Hitachi Unified Storage Hardware Service Guide Out ...
Page 40: ...xl Hitachi Unified Storage Hardware Service Guide ...
Page 152: ...5 8 Replacing a cache backup battery Hitachi Unified Storage Hardware Service Guide ...
Page 156: ...6 4 Replacing a Fan Module Hitachi Unified Storage Hardware Service Guide ...
Page 180: ...8 16 Adding and replacing controllers Hitachi Unified Storage Hardware Service Guide ...
Page 188: ...9 8 Replacing cache memory Hitachi Unified Storage Hardware Service Guide ...
Page 200: ...11 6 Replacing the Host connector Hitachi Unified Storage Hardware Service Guide ...
Page 204: ...12 4 Replacing the Drive I O Module Hitachi Unified Storage Hardware Service Guide ...
Page 212: ...14 4 Replacing the SAS ENC cable Hitachi Unified Storage Hardware Service Guide ...
Page 274: ...17 14 Troubleshooting Hitachi Unified Storage Hardware Service Guide ...
Page 291: ...1 Hitachi Unified Storage Hardware Service Guide ...