Saving the Test Results
Saves using W-IR mode
"HIOKI E.E. CORPORATION","ST5680","Ver.","V1.00"
"Serial No.","123456789"
Header
"DATE","2021/10/25"
"TIME","20:03:01"
Save date and time
"MODE","WIR"
"MODE","W"
"FREQUENCY","DC ",""
"TEST VOLTAGE"," 300","V"
"START VOLTAGE"," 0","%"
"TEST TIME"," 0.4","s"
"RISE TIME"," 0.1","s"
"FALL TIME","OFF",""
"DELAY TIME","OFF",""
"UPPER LIMIT"," 2.000","mA"
"LOWER LIMIT","OFF",""
"ARC","OFF"
"ARC LIMIT"," 1","mA"
"OFFSET CANCEL","0"
"CONTACT CHECK","OFF"
"AUTO RANGE","1"
"KEEP DATA","0"
"MODE","IR"
"TEST VOLTAGE"," 1000","V"
"TEST TIME"," 0.4","s"
"RISE TIME"," 0.1","s"
"FALL TIME","OFF",""
"DELAY TIME","OFF",""
"UPPER LIMIT","OFF",""
"LOWER LIMIT"," 0.5000 ","Mohm"
"OFFSET CANCEL","0"
"CONTACT CHECK","OFF"
"AUTO RANGE","1"
"KEEP DATA","0"
Test conditions
"MODE","W"
"START TIME","2021/10/25 20:02:54"
"VOLTAGE"," 2.957E+02","V"
"CURRENT"," 2.441E-05","A"
"RESISTANCE"," 0.000E+00","ohm"
"ELAPSED TIME"," 0.0","s"
"TIMER TYPE","0"
"JUDGE","PASS"
"MODE","IR"
"START TIME","2021/10/25 20:02:54"
"VOLTAGE"," 9.943E+02","V"
"RESISTANCE"," 9.500E+05","ohm"
"ELAPSED TIME"," 0.0","s"
"TIMER TYPE","0"
"JUDGE","PASS"
Test results, judgment results
(JUDGE setting is on)
HIOKI ST5680A961-00
Summary of Contents for ST5680
Page 2: ...HIOKI ST5680A961 00 ...
Page 84: ...84 Individually Executing Specific Steps HIOKI ST5680A961 00 ...
Page 118: ...118 Key Lock HIOKI ST5680A961 00 ...
Page 154: ...154 Calibration Expiration Check Function HIOKI ST5680A961 00 ...
Page 182: ...182 Internal Circuit Configuration HIOKI ST5680A961 00 ...
Page 220: ...220 Option Specifications HIOKI ST5680A961 00 ...
Page 238: ...238 External View 16 4 External View Unit mm HIOKI ST5680A961 00 ...
Page 250: ...250 HIOKI ST5680A961 00 ...
Page 253: ...www hioki com HIOKI ST5680A961 00 ...