4.4 Setting Event Detection [REC&EVENT]
70
An event is recorded when high frequency impulse noise is imposed on the
mains voltage waveform.
Setting Transient Events
Move to the setting item.
Select the screen.
1
2
Setting Contents
OFF/ ON (disable/enable transient event recording)
Select from the pull-down menu.
4
Accept
Cancel
An event is detected as the presence, during any single cycle of the mains voltage wave-
form, of a frequency component at 10 to 100 kHz with 50 Vrms (±70.7 Vpeak equivalent) or
greater amplitude in either the positive or negative direction on any of the three channels.
See:
"Transient Overvoltage" (p. 112)
3
OFF
ON
What is a transient?
On this instrument, a "transient overvoltage" is also called a "transient".
Transient overvoltage is sometimes also called an "excessive voltage spike" or "Impulsive voltage".
Only the existence or non-existence of transient overvoltage is detected.
Although voltage and current waveforms can be displayed when an event is
detected, the transient overvoltage waveform cannot be displayed.
Summary of Contents for 3197
Page 1: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...
Page 2: ......
Page 8: ...Contents vi ...
Page 30: ...1 3 Measurement Flowchart 22 ...
Page 44: ...2 5 Internal Operating Status and Memory Usage 36 ...
Page 86: ...4 6 Initializing the Instrument System Reset 78 ...
Page 134: ...6 4 Viewing Recorded Data REVIEW State 126 ...
Page 176: ...9 4 Disposing of the Instrument 168 ...
Page 199: ......
Page 200: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...