![Hioki 3197 Instruction Manual Download Page 107](http://html.mh-extra.com/html/hioki/3197/3197_instruction-manual_2137178107.webp)
6.1 Viewing Instantaneous Data (VIEW Screen)
99
6
Harmonics can be displayed in a bar graph or in a list. The display method
is selected by the F1 key.
Displaying Harmonics
[HARMONICS]
Select the screen.
The bar graph and list selection changes
each time you press the key.
Voltage
To view the values of each harmonic
order
Green indicates the cursor posi-
tion.
Move the cursor to read the value
of each harmonic order.
Press the right or left cursor key to
move the cursor in the respective
direction.
Current
Active Power
Displaying the harmonics bar graph
The harmonics bar graph displays voltage, current and power from the fundamental
waveform to the 50th order.
In the bar graph, yellow indicates positive values and red indicates negative values.
Voltage total harmonic distortion (THD) is also displayed.
Voltage Total Harmonic
Distortion
Select the bar graph [GRAP/
LIST] display
1
2
Changes in the sequence: Channels that
can be switched are determined by the wir-
ing configuration.
To change the displayed channel
The channel changes each time
you press the key.
CH1
CH2
CH3
The voltage harmonic calculation method (RMS [V]
↔
Content Percentage [%])
can be changed on the SYSTEM-[MEASURE] screen (p. 62).
Summary of Contents for 3197
Page 1: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...
Page 2: ......
Page 8: ...Contents vi ...
Page 30: ...1 3 Measurement Flowchart 22 ...
Page 44: ...2 5 Internal Operating Status and Memory Usage 36 ...
Page 86: ...4 6 Initializing the Instrument System Reset 78 ...
Page 134: ...6 4 Viewing Recorded Data REVIEW State 126 ...
Page 176: ...9 4 Disposing of the Instrument 168 ...
Page 199: ......
Page 200: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...