8.4 Function Specifications
152
8.4
Function Specifications
Display
SYSTEM
Settings
VIEW
Waveforms, DMM, vectors, harmonics (bar graph/list)
TIME PLOT
Voltage (½), voltage, current, frequency, active power, power factor,
voltage total harmonic distortion, voltage unbalance factor, energy
consumption, demand
EVENT
Event list, event monitor, event waveform, event voltage fluctuation
graph, inrush current graph
Setting Contents (factory defaults in bold)
Measurement frequency
AUTO, 50 Hz, 60 Hz
Phase colors (input
terminal colors)
TYPE1, TYPE2, TYPE3, TYPE4, TYPE5
Phase names
R S T, A B C, L1 L2 L3, U V W
Wiring Configuration
1P2W, 1P3W, 3P3W2M, 3P3W3M, 3P4W, 3P4W2.5E
Nominal Line Voltage
AUTO, 100, 101, 110, 120, 127, 200, 202, 208, 220, 230, 240, 277,
347, 380, 400, 415, 480, 600 or VALIABLE (VALIABLE = any integer
from 50 to 600 V)
Clamp sensors
Models 9660, 9661, 9667_500, 9667_5k, 9669, 9694, 9695-02, 9695-
03, 9657-10 or 9675
Current range
PT ratio
1
, 60, 100, 200, 300, 600, 700 or
VALIABLE
(1.00 to 999.99)
CT ratio
1, 4, 6, 8, 10, 12, 15, 20, 30, 40, 60, 80, 100, 120, 160 or VALIABLE
(0.01 to 999.99)
Harmonic voltage
calculation
Rms value, percentage content
Power factor calculation
Power factor
/displacement power factor
(PF/DPF)
Memory partitioning
ON / OFF
Interval
AUTO, 1, 5, 15 and 30 min., and 1 hour (AUTO sequentially selects
1, 2, 10, 30 seconds, 1, 5, 15 and 30 min., and 1 hour automatically)
Clamp Model
Measurement range
9657-10, 9675
500.0 mA, 5.000 A
9694, 9695-02
5.000 A, 50.00 A
9660, 9695-03
10.00 A, 100.0 A
9661, 9667
(using 500 A range)
50.00 A, 500.0 A
9669
100.0 A, 1.000 kA
9667
(using 5 kA range)
500.0 A, 5.000 kA
Summary of Contents for 3197
Page 1: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...
Page 2: ......
Page 8: ...Contents vi ...
Page 30: ...1 3 Measurement Flowchart 22 ...
Page 44: ...2 5 Internal Operating Status and Memory Usage 36 ...
Page 86: ...4 6 Initializing the Instrument System Reset 78 ...
Page 134: ...6 4 Viewing Recorded Data REVIEW State 126 ...
Page 176: ...9 4 Disposing of the Instrument 168 ...
Page 199: ......
Page 200: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...