8.2 Detailed Specifications of Measurement Parameters
146
[Displacement
Power Factor]
DPF
Measurement method
Calculated from phase difference between fundamental
voltage and current waveforms, 200 ms calculation
Measurement range
-0.000 to -1.000 (leading), +0.000 to +1.000 (lagging)
0.0000 to 1.0000 (leading), + 0.0000 to + 1.0000
(lagging)
Measurement accuracy ±1 dgt. of calculation from each measurement value
Polarity indication
No sign for lagging phase (current lags voltage)
Minus sign (–) for leading phase (current leads voltage)
Non-Input display
“1.000”(when voltage or current is zero)
[Energy
Consumption]
Measurement
parameter
Active power value: WP+ (consumption), WP- (regener-
ation)
Reactive power value: WQLAG (lagging), WQLEAD
(leading)
Active or reactive power value (selectable)
Measurement method
Cumulative consumption and regeneration are
calculated separately using active power
Cumulative lagging and leading values are calculated
separately using reactive power
Measurement accuracy
±1 dgt. applied to active and reactive power measure-
ment accuracy
Time accuracy
±10 ppm ±1s (@23ºC, 73ºF)
[DEMAND]
Measurement
parameter
Active or reactive power demand (selectable)
Active power demand (3-phase total value)
Pdem+ (consumption only), Pdem (regeneration only)
Reactive power demand (3-phase total value)
QdemLAG (Lagging only), QdemLEAD (Lagging only)
Measurement method
Calculated using active or reactive power within the de-
mand calculation period
Measurement accuracy
±1 dgt. applied to active and reactive power
measurement accuracy
Measurement Parameter
Summary of Contents for 3197
Page 1: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...
Page 2: ......
Page 8: ...Contents vi ...
Page 30: ...1 3 Measurement Flowchart 22 ...
Page 44: ...2 5 Internal Operating Status and Memory Usage 36 ...
Page 86: ...4 6 Initializing the Instrument System Reset 78 ...
Page 134: ...6 4 Viewing Recorded Data REVIEW State 126 ...
Page 176: ...9 4 Disposing of the Instrument 168 ...
Page 199: ......
Page 200: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...