Fingerprint Access Control Terminal
21
Access Control System Parameters Interface
Figure 4. 36
2.
Edit the parameters.
Terminal
Authentication:
Configure the terminal authentication mode, including
“Card/FP (Fingerprint)”, “Card”, “Fingerprint”, “Card and PW
(Password)”, “Card and FP (Fingerprint)”, “FP (Fingerprint) and
PW (Password)”, “Card and FP (Fingerprint) and PW
(Password)”, and “Card/PW (Password) (The password here
refers to the card ID No. and the user password)”.
Sub Reader
Authentication:
Configure the sub reader authentication mode, including
“Card/FP (Fingerprint)”, “Card”, “Fingerprint”, “Card and PW
(Password)”, “Card and FP (Fingerprint)”, “FP (Fingerprint) and
PW (Password)”, “Card and FP (Fingerprint) and PW
(Password)”, and “Card/PW (Password) (The password here
refers to the card ID No. and the user password)”.
Door Magnetic:
Configure the door magnetic status, including Remain Closed
and Remain Open.
Note:
By default, the magnetic status is Remain Closed.
Lock Action
Time:
Configure the action time after the door opening. After the
action time, the door will be locked.
Note:
Available lock action time duration is from 1 to 255s.
Door-Open
Timeout Alarm:
Configure the maximum time duration for door opening. If the
door-open time has exceeded the configured value, it will
trigger an alarm.
Auth Times
Exceeded
Alarm
Configure the maximum times for authentication.
Anti-passback:
Enable the Anti-passback function and configure the anti-
passing back path via the client software. Follow the
configured path to open/close the door.
Note:
The Wiegand direction should be
Receive
.
3.
Press the ESC key and select
Yes
to save the settings and exit the interface.
4.5.2
Configuring Holiday Group
Purpose:
Configure the access control system holiday schedule. The door can be open during the holiday.
4.5.2.1
Adding Holiday Group
Steps: