CHAPTER 5
General Maintenance and Troubleshooting
72
intellaspot
TM
XT-1 User Manual
Cleaning the Fixture
Lenses, Dichroics and Lithos
To clean the internal glass components:
1. Disconnect power to the fixture. If the fixture has been operating, allow the fixture to cool
before handling.
2. Remove the bezel by loosening the four captive screws on each side.
3. Clean the dichroics, lithopattern and effects, color wheels, and lens using a mild glass cleaner
(containing no ammonia) and a soft, lint-free cotton cloth.
4. All glass parts should be cleaned with using a mild glass cleaner (containing no ammonia) and
a soft, lint-free cotton cloth.
Filters
There are five washable
filters in intellaspot XT-1
fixtures. Two are behind
the intake vents on the
electronics housing. Two
are located on the inside of
one head cover and one on
the other head cover.
To clean the filter:
1. Remove the filter from
its location.
2. Wash with soap and
water.
3. Allow to dry and then
re-insert.
Warnings:To avoid electrical shock, disconnect power before servicing.
Equipment surfaces may reach temperatures up to 130° C (266° F).
Allow the fixture to cool before handling.
A filter next to each handle
are easily removed from
the outside of the housing.
Bezel filters are located on the
inside of each cover over air
intakes.
of the electronic housing
Summary of Contents for intellaspot XT-1
Page 8: ...viii intellaspotTM XT 1 User Manual...
Page 14: ...xiv intellaspotTM XT 1 User Manual...
Page 20: ...CHAPTER 1 Product Overview 6 intellaspotTM XT 1 User Manual...
Page 30: ...CHAPTER 2 Setup and Configuration 16 intellaspotTM XT 1 User Manual...
Page 72: ...CHAPTER 4 Fixture Programming 58 intellaspotTM XT 1 User Manual...
Page 98: ...Appendix B Important Safety Information 84 intellaspotTM XT 1 User Manual...