CHAPTER 5
General Maintenance and Troubleshooting
intellaspot
TM
XT-1 User Manual
73
Troubleshooting
System State LEDs
Five labeled LEDs on the display panel indicate the following system activity:
Board LED States
LEDs located on the CPU, 2-phase, 3-phase, and Data Communication boards help you
troubleshoot the unit.
Name Color
State
Problem
?
Description
Status
Green
On
No
(45 sec On/1.4 sec.Off) Running normal motion-control code
Off
Yes
Fixture code not running
Lamp
White
On
No
Lamp is on
Off
Maybe
Lamp is off
If the Status Lamp is also off, Check that the harness is connected
from the HD1 on the LED status board to HD8 on the Tilt board
Blinking
No
Lamp is either cooling down or in a indeterminate state
CPU
Amber
Steady
No
Fixture is running code
PSU
Blue
Steady
No
40V Power Supply is running
5V
Red
Steady
No
Fixture’s Motion Control system is receiving power
Location
LED #
State
Problem?
Description
2-phase
board
LD1-LD4
Green
No
S1-S4 sensor open
Yellow
No
S1-S4 sensor closed
Flashing red
No
Board is ready to initialize
Infinitely flashing red
Yes
Board not receiving data
Red
Yes
Board not receiving data
Flashing red and green
Yes
Addressing screw(s) missing from board
Sporadically flashing
green& yellow
Yes
2 boards are addressed the same. (Move
addressing screw to appropriate location)
OFF
Yes
Board not receiving power
LD5
Green
No
Receiving data
Dim green
Yes
Board not receiving data
OFF
Yes
Board not receiving power
Summary of Contents for intellaspot XT-1
Page 8: ...viii intellaspotTM XT 1 User Manual...
Page 14: ...xiv intellaspotTM XT 1 User Manual...
Page 20: ...CHAPTER 1 Product Overview 6 intellaspotTM XT 1 User Manual...
Page 30: ...CHAPTER 2 Setup and Configuration 16 intellaspotTM XT 1 User Manual...
Page 72: ...CHAPTER 4 Fixture Programming 58 intellaspotTM XT 1 User Manual...
Page 98: ...Appendix B Important Safety Information 84 intellaspotTM XT 1 User Manual...