Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
3. If you are removing the access panel as part of a non-hot-plug installation or maintenance procedure, remove all
power from the server:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
c. Disconnect all peripheral cables from the server.
4. If installed, unlock and remove the security padlock and/or the Kensington security lock.
For more information, see the lock documentation.
5. If the front bezel key is hanging from the padlock eye, remove the key.
6. Do one of the following:
• Server in tower mode:
Position the tower server for hardware configuration.
Extend the server from the rack.
7. Remove the access panel:
a. If necessary, unlock the access panel latch.
b. Press the release button and pull up the latch to disengage the access panel from the chassis.
c. Lift up the rear side of the access panel to remove the panel from the chassis.
Operations
43
Summary of Contents for ProLiant ML350 Gen10
Page 28: ...NVMe drive bay numbering Tower orientation Rack orientation 28 Component identification ...
Page 31: ...Component identification 31 ...
Page 33: ...Open the front bezel Procedure 1 Unlock the front bezel 2 Open the front bezel Operations 33 ...
Page 178: ...Cable color Description Blue Front I O cable Orange Front USB cable 178 Cabling ...