Configuration
APS-90, APS-180 and APS-90-Outdoor-PoE
If measurement is not possible - e.g. a consistently level floor area is not
big enough - the device presents a ‘not available’ hint (Fig. 81 /1). In this
case use a separate measuring device and set up the values manually.
The height is the distance between the device level and the floor level.
■
To perform a new measurement click the
Refresh
■
To apply the measured values click the
Save Auto Calibration
■
Set up the values manually for the pitch (Fig. 81 /8) and yaw (Fig. 81 /7) angle or the
height (Fig. 81 /10) by inputting a value directly into the input field (Fig. 81 /9) or using
the spin control (Fig. 81 /2).
■
To go back to the last saved settings click the
Reset
■
To save all the settings in the device click the
Save
6.4.2
Height Range
Define the height range for the APS. The displayed ranges depends to the used device.
Low range
■
2 m to 2,5 m for APS-90 and APS-90-Outdoor-PoE
■
not available for APS-180
Standard range
■
2,3 m to 4 m for APS-90 and APS-90-Outdoor-PoE
■
3 m to 6 m for APS-180
Extended range
■
3,5 m to 6 m for APS-90 and APS-90-Outdoor-PoE
■
5 m to 9 m for APS-180