the solar heater to heat before allowing the next heater to start. If
the solar heater meets the demand within this time frame, the next
heater will not be used. Note that a time interval setting of “0” will
eliminate priority and always run both heaters at the same time.
Minimum Operation Speed?
For variable speed pumps, select the lowest
pump speed that is allowed while heating. Set a speed that will ensure that
there will be sufficient flow for the heater to operate properly.
If Heat Pump is selected:
Name Heater:
Select the box, then type the desired name for your heater. This
name will be used when referring to this particular heater.
Which Relay is it Wired to?
Selecting the box will bring you to a table showing
only one selection. Advance to the next screen to continue heat pump configu-
ration.
If more than one heater has been configured:
Heater Priority Duration?
Set the amount of time that you will allow
the solar heater to heat before allowing the next heater to start. If
the solar heater meets the demand within this time frame, the next
heater will not be used. Note that a time interval setting of “0” will
eliminate priority and always run both heaters at the same time.
Minimum Allowed Air Temperature for Heater?
If the air temperature falls
below this setting, the heater will be prevented from running, regardless of
conditions. This feature is especially useful for heat pumps which become less
efficient as the outdoor ambient temperature falls.
Minimum Operation Speed?
For variable speed pumps, select the lowest
pump speed that is allowed while heating. Set a speed that will ensure that
there will be sufficient flow for the heater to operate properly.
If Solar is selected:
Name Heater
Select the box, then type the desired name for your heater. This
name will be used when referring to this particular heater.
Does the Solar Heater Have a Pump?
Select whether the solar heating sys-
tem has a dedicated recirculation pump. If so, the OmniHub will turn this pump
on when the pool temperature is below the heater setting and there is solar
heat available.
If Yes is selected:
Which Relay is it Wired to?
Selecting the box will display all con-
nected Smart Relays. Select the Smart Relay that is wired to the
Solar pump.
Does the Solar Heater Have a Valve?
Select whether the solar heating sys-
33