controlled independently.
Select Equipment -
After selecting the desired interlock statement, use the
buttons labeled “Flow Switch” and “Equipment” located below the interlock
statement to choose the flow switch and equipment that you would like to
interlock. Pressing either button will bring you to another screen with all of the
possible equipment that can be interlocked. Choose the desired flow switch
and equipment then press save to lock in those values.
After saving the equipment, the interlock statement will change to include your
selected equipment. Verify that the interlock statement correctly states the in-
terlock that you would like to create and then press save to create the interlock.
If Equipment to External Input is selected (requires that you have an external input
configured):
Select Interlock Statement -
Use the right and left arrows to choose the de-
sired behavior of the interlock. The behavior for each interlock statement is
described below.
If the External Input is closed, the Equipment can not be on -
The Equip-
ment can only turn on if the External Input is open. If the Equipment is running
and then the External Input becomes closed, the Equipment will turn off. The
Equipment can be controlled independently as long as the External Input is
open.
If the External Input is open, the Equipment can not be on -
The Equipment
can only turn on if the External Input is closed. If the Equipment is running and
then the External Input becomes open, the Equipment will turn off. The Equip-
ment can be controlled independently as long as the External Input is closed.
If the External Input is closed, the Equipment is forced on -
The Equipment
is always off until the External Input becomes closed, at which time the Equip-
ment will remain on until the External Input becomes open again. The Equip-
ment cannot be controlled independently.
If the External Input is closed, the Equipment is forced off -
The Equipment
is always on until the External Input becomes closed, at which time the Equip-
ment will remain off until the External Input becomes open again. The Equip-
ment cannot be controlled independently.
Select Equipment -
After selecting the desired interlock statement, use the
buttons labeled “External Input” and “Equipment” located below the interlock
statement to choose the external input and equipment that you would like to
interlock. Pressing either button will bring you to another screen with all of the
possible equipment that can be interlocked. Choose the desired external input
and equipment then press save to lock in those values.
45
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS