Final Steps
With the wiring complete, find the Wiring Hub's cover. The inside of the cover is made of foam and
contains precut removable gaskets (shown below) that can be used to seal the low voltage exit.
Remove a gasket and wrap it around the low voltage wiring at the exit of the Wiring Hub. Work the
gasket into the exit slot until it is fully sealed then fasten the cover to the Wiring Hub.
System Startup
After confirming that all wiring has been performed according to NEC and local codes and that the
Wiring Hub is properly grounded, apply power to the OmniHub. The OmniHub will take about 30
seconds to fully start.
Firmware Upgrade
The OmniHub's firmware is the basic operating system that runs the system. The OmniHub was
shipped with the version of firmware that was available at the time of release. There may be a newer
version available and if so, we encourage you to upgrade. Also, if you have experienced problems,
Hayward Technical Support may advise you to upgrade your OmniHub's firmware. To upgrade the
OmniHub firmware, refer to the procedure shown in the OmniHub Operation Manual. Upgrading
firmware can be performed before or after Configuration but should be done before the OmniHub
begins operation.
Hub Cover (inside)
Gasket
Bottom of Hub Enclosure
23