Permitted User Setting -
The OmniHub will automatically calculate
these values based on the minimum and maximum RPM that were
previously entered. They can be changed as desired.
Speed Presets -
Set the Low Pump Speed %, Medium Pump Speed
%, and High Pump Speed %, presets. These presets will be used
when setting schedules for your pump.
Does Accessory have a Valve?
Select whether the accessory requires a valve to change
position when in use.
If Yes is selected:
How Many?
Select how many valves are used for the accessory.
Where is the Valve(s) Wired?
Selecting the box will bring you to a table show-
ing all detected low voltage relays. Select the relay(s) that is wired to the ac-
cessory valve(s), then advance. The valve(s) should now be shown in the box.
Advance to the next screen to continue accessory configuration.
Would You Like to Enable Priming?
If a VSP or two-speed pump is used, select whether
you want the pump to prime when turned on. This will turn the pump on at high speed for
3 minutes to establish normal water flow every time the pump is activated after being off
for at least 30 seconds.
If Yes is selected:
Enter Priming Duration:
Input the number of minutes that you want the pump
to prime for. This setting is configurable from 0-15 minutes. Once priming has
finished, the pump will run in the speed that it was chosen to run at.
Freeze Protection Enabled?
Freeze protection is used to protect the pool and plumbed
equipment against freeze damage during cold temperatures. If freeze protection is en-
abled AND the air temperature falls below the freeze threshold (refer to pump configura-
tion), the OmniHub will turn on the accessory pump to circulate the water.
If Yes is selected:
Freeze Protect Speed?
This is the speed of the pump while freeze protection
is active. Select the desired pump speed %. NOTE: this option only appears if
the pump is a two speed pump or a variable speed pump.
Do You Have an Air Temperature Sensor?
Select whether there is an air temperature sensor wired
to the OmniHub.
If Yes is selected:
Where is the Sensor Wired?
Touching the box will bring you to a table showing all
detected sensors connections. Select the sensor connection used for the air sensor (typi-
cally SENS2) and touch the Done button. The sensor connection should now be shown in
the box and you can advance to the next screen to continue configuration.
41