Black/W
hit
e
G
ray
Black
Red/W
hit
e
Red
230 VAC
Two Speed
Line 2 in
Line 1 in
Common
Low Speed
Input
Wiring
Black/W
hit
e
G
ray
Black
Red/W
hit
e
Red
Smart Relay 2
Smart Relay 1
High Speed
Powering a 230 VAC Two Speed Pump
A 230 VAC two speed pump requires the use of two Smart Relays. Refer to the diagram below.
Smart Relay LEDs and On/Off button
Although the Smart Relay will be automatically controlled by the Hub, it does feature a manual On/
Off button as well as two indicator LEDs. If communication has been interupted or lost to the Wiring
Hub, the Smart Relay's On/Off button will allow you to toggle back and forth between power states.
This button will not be functional during normal operation.
Refer to the table below when viewing the Smart Relay's indicator LEDs. Note that when the "Relay
On" LED is OFF, the relay is in an OFF state and there is no power going out to the load. When Green,
the relay is energized and the load receives power.
Remote LED
Relay On LED
Indication
Off
Off
No power or firmware failure
Red On for 1
sec, Off for 6
sec
Off or Green
There is no communication with the Wiring Hub - the
relay can be manually controlled using the On/Off
button
Green On
Off or Green
There is communication with the Wiring Hub - this indi-
cates normal operation and On/Off button is disabled
Green 3 fast
blinks
Off or Green
User attempted to use the On/Off button manually
while the Smart Relay is being automatically controlled
by Wiring Hub (not allowed)
Blinking
Blinking
Firmware upgrade in progress
17