valves are turning.
Flow Monitoring -
Select whether you want flow to be monitored.
Priming -
Select whether you want the Filter Pump to prime. This option only
appears if the Filter Pump is configured as a 2-speed or variable speed pump.
Freeze Protect -
Select whether you want the Filter Pump to turn on for freeze
protection. Also set the freeze protect air temperature threshold from this
menu. Freeze protect operation can be overridden for a 60 minute period. (See
Operation manual for more information).
If Heaters is selected:
Add a Heater -
Pressing “Add a Heater” from this screen will take you through
the full configuration for adding a new heater. These steps are described in the
Advanced Configuration Guide section of this manual.
General Heater Options -
Pressing this button will take you to a screen will the
following general options for heater operation:
Extend -
If “Enabled”, the filter extend logic keeps the filter pump running
beyond the normal turn-off time until the water is heated up to the desired
temperature setting. Heater extend will NOT cause the filter pump to turn on, it
will only delay the turn off time when the heater is operating.
Cooldown -
This feature ensures that the heater cools down before water cir-
culation is stopped. When enabled, the OmniHub will continue to run the filter
pump for 5 minutes after the heater turns off.
Max Temperature -
Select the maximum allowed heater setpoint temperature.
Select a Heater -
Once you select a heater, all of the options for that heater will
appear on the next screen. These options are as follows:
Name -
Create a custom name if desired.
Type -
Select the type of heater that is configured (Solar, Heat Pump, Gas).
Relay -
Select the relay that is wired to the heater. This option is only available
if the heater is configured as a heat pump or a gas heater.
Min Filter Speed -
Select the minimum speed that the Filter Pump will run while
the heater is active. This option is only available for 2-speed and VSP pumps.
Min Air Temperature -
Select the minimum air temperature that the heater will
be allowed to run. This option is only available if the heater is configured as a
Heat Pump.
49