will select.
If Yes is selected:
ORP Setpoint
- Set the desired ORP level which is measured in mV. 650mV
is the default. The OmniHub will continuously measure ORP and generate/
dispense the proper amount of chlorine to maintain this setpoint.
ORP Timeout
- Select a timeout interval. If the OmniHub has been chlorinating
for more than the selected ORP timeout without reaching the desired level, the
chlorinator will turn off and display an alarm. The user must clear the alarm to
resume chlorination.
Type of Chlorinator?
Select the Hayward TurboCell model (if using an Aqua
Rite), liquid chlorinator or tablet feeder that is installed in your system. Note that
a flow switch must be installed and connected directly to the Aqua Rite, if that
is the chlorinator selected.
If TurboCell model is selected:
Where is the Cell Located?
If an entry is already shown in the
box, touch the Advance button. If no entry is shown, selecting
the box will bring you to a table showing the detected cell. Se-
lect the TurboCell and select Done.
If Liquid Chlorinator is selected:
Select Relay -
Selecting the box will bring you to a table show-
ing all Smart Relays. Select the Smart Relay that is connected
to the Liquid Chlorine dispenser.
If Tablet Feeder is selected:
Where is the Valve Wired? -
Selecting the box will bring you
to a table showing all valve outputs. Find the valve that is con-
nected to the Tablet Feeder. Select the valve and select Done.
If No is selected:
Do You Have a Salt Water Chlorine Generator?
Requires Hayward Aqua Rite
If Yes is selected:
Type of Cell?
Select the type of Hayward TurboCell that is installed
in your system.
Where is the Cell Located?
If an entry is already shown in the box,
touch the Advance button. If no entry is shown, selecting the box will
bring you to a table showing the detected cell. Select the TurboCell
and select Done.
Percentage of Outpu
t - The OmniHub can only generate chlorine
while the filter pump is operating. Set the percentage of run time that
you desire chlorine generation. Raise this value to generate more
chlorine. Lower this value to generate less.
35