After saving the equipment, the interlock statement will change to include your
selected equipment. Verify that the interlock statement correctly states the in-
terlock that you would like to create and then press save to create the interlock.
NOTE: Freeze Protection will override External Interlocks for Filter Pumps
but not for any other equipment.
If Equipment to Temp. Sensor is selected:
Select Interlock Statement -
Use the right and left arrows to choose the de-
sired behavior of the interlock. Selections are described below .
If the Temp. Sensor reads greater than Temperature degrees F, the Equip-
ment can not be on -
The Equipment can only be turned on if the Temp.
Sensor reads less than the selected Temperature setpoint. If the Equipment is
running and then the Temp. Sensor reaches the selected Temperature setpoint,
the Equipment will turn off. The Equipment can be controlled independently as
long as the Temp. Sensor reads less than the selected Temperature setpoint.
If the Temp. Sensor reads less than Temperature degrees F, the Equip-
ment can not be on -
The Equipment can only be turned on if the Temp. Sensor
reads greater than the selected Temperature setpoint. If the Equipment is run-
ning and then the Temperature goes below the selected Temperature setpoint,
the Equipment will turn off. The Equipment can be controlled independently as
long as the Temp. Sensor reads greater than the selected Temperature setpoint.
If the Temp. Sensor reads greater than Temperature degrees F, the Equip-
ment is forced on -
The Equipment is always off until the Temp. Sensor reads
greater than the selected Temperature setpoint, at which time the Equipment
will remain on until the Temperature falls back below the setpoint. The Equip-
ment cannot be controlled independently.
If the Temp. Sensor reads greater than Temperature degrees F, the Equip-
ment is forced off -
The Equipment is always on until the Temp. Sensor reads
greater than the selected Temperature setpoint, at which time the Equipment
will remain off until the Temperature falls back below the setpoint. The Equip-
ment cannot be controlled independently.
Select Equipment -
After selecting the desired interlock statement, use the
buttons labeled “Temp. Sensor”, “Temperature” and “Equipment” located below
the interlock statement to choose the temperature sensor, temperature and
equipment that your would like to interlock. Pressing any of these buttons will
bring you to another screen with all of the possible equipment that can be inter-
locked. Choose the desired temperature sensor, temperature and equipment
then press save to lock in those values.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS