WARNING: Disconnect primary power prior to servicing.
Section 4 Theory of Operation
Maxiva ULX COFDM Series
4.7.2
Leak Detector and Cabinet Drains
A leak detector is installed at the bottom of the cabinet. The leak detector is shown in
Figure 4-21 on page 4-48. It is mounted in the bottom cabinet near the center. The leak
detector consists of a small reservoir with a float. The TCU monitors this leak detector
to alert the system should a leak occur. A leak detection will cause the transmitter and
the pump to be shut off by activating the pump interlock signal. In order to reset the leak
detector the float must be removed and a drain plug removed. Removing the drain plug
allows the reservoir to drain into the drip pan at the bottom of the cabinet.
The cabinet can be emptied of coolant by opening the fittings at the end of the supply
and return side drain hoses. Use a 7/16" open end wrench to open the drain valves.
Figure 4-21 Leak Detector and Cabinet Drains
Leak
Detector
Return Side
Drain Hose
Supply Side
Drain Hose
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...