10/6/10
888-2629-200
3-15
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Maxiva ULX COFDM Series
3.7
Output Main Screen
If you press the Output button on the HOME screen, it will take you to
the screen shown in Figure 3-10. The Output Menu structure is shown
in Figure 3-25 on page 3-29.
Figure 3-10 Output Screen
The main Output screen is has 3 main areas:
•
RF Output System - This panel gives the total system Forward and Reflected
power, measured after the filter. It also has a VSWR and Foldback status
indications with backgrounds that are red for fault or yellow for warning. A
VSWR fault is indicated when the system VSWR is > 1.9:1. Foldback
warning is indicated when system VSWR is > 1.4:1
NOTE:
Both VSWR fault and foldback levels are adjustable via software.
•
Power Amplifier Cabinet - Amplifier cabinet icons (triangle) give a status
indication of OK (green) or Fault (red) along with cabinet Forward and
Reflected power (before the filter) for each cabinet.
•
Output Control - The control area at the bottom of the screen is used to
control an external RF switch so that the transmitter can be switched from
Antenna to the Test Load. The diagram indicates the position of the RF
switch based on micro-switches located on the switch.
To Figure 3-11
To Figure 3-4
Cabinet Indicators
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...