2-6
888-2629-200
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Maxiva ULX COFDM Series
2.4
Transmitter Cabinet Placement
The transmitter cabinet should be placed where it will have approximately 1 meter
clearance on each side and in the back. The front of the transmitter should have a
clearance of at least 1.5 meters to allow access for removal and installation of the PA
modules.
There are several drawings included in the drawing package to help plan the
cabinet placement:
•
Outline Drawing
•
RF Equipment Layout
•
Liquid Cooling System Layout
STEP 1
Remove the bolts or straps holding the transmitter to the wooden pallet
and carefully slide the cabinet off the pallet.
STEP 2
Remove rear door and set aside in a safe place for the rest of the
installation process.
MULTI-CABINET MODELS:
STEP 3
Place cabinets in position and carefully align.
ALL MODELS:
STEP 4
Use levelling shims under transmitter cabinet as required to make sure
the transmitter is level and solid (not rocking).
STEP 5
Install Drip Tray. The aluminum drip tray slides under the transmitter
just below the rear door panel. The drip tray rests on the floor and is
centered underneath the rear of the Maxiva transmitter. It should be
checked periodically for presence of coolant.
NOTE:
Do not open the packaging for, or install IPA (driver), or PA modules at this time.
These will be installed just before the initial turn on.
2.5
Cooling System Installation
The major components of the Maxiva cooling system include the TCU (pump control
card), pump module/heat exchanger, and the interconnecting plumbing. The installation
procedures will rely heavily on the following documentation:
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...