WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Maxiva ULX COFDM Series
a.
Electrical Installation Diagram
b.
AC Power Flow Diagram
c.
Cooling System Electrical Diagram
d.
Liquid Cooling System Layout
e.
Cooling System Outline
f.
Appendix B chapter in this manual
g.
Pump Module/Control Panel & Heat Exchanger manufacturer’s instruction
manuals
2.5.1
Heat Exchanger and Pump Module Installation
When planning the installation, keep the following restrictions in mind:
The heat exchanger unit is typically installed outdoors. Locate the unit outside of the
building or on the roof, as close as possible to the transmitter to minimize piping and
pumping requirements and costs.
If mounted outside the building, but not on the roof, make sure a concrete pad is poured
and allowed time to cure before setting the heat exchanger module in place. Plan to
unload the heat exchanger module unit directly to its final location.
Allow extra space for the concrete in front of, beside and behind the unit to avoid dirt
being blown around by the fans, and to allow walking and working space for
maintenance and inspection of the unit.
When mounting on a roof, install unit such that building columns or load bearing walls
adequately support it, also, include room around the unit for access during installation
and maintenance
The heat exchanger must be installed level. Plan to fasten the mounting legs securely to
the supporting steel (for roof installation) or to the concrete pads.
Plan to orient the unit so that plumbing elbows are minimized and complex plumbing
assemblies like back to back elbows are not required. If hoses are used in the coolant
system, position them to avoid sharp bends where flow could be disrupted. In addition,
the heat exchanger should be oriented so that access to the switches, fans, fan motors is
convenient.
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...