3-10
888-2629-200
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Maxiva ULX COFDM Series
1.
Auto/Manual - Auto should be the standard position for normal operation.
Placing it in Manual mode prevents an autoswitch to the alternate drive
chain. In AUTO mode, if the on-air exciter drops below 50% of nominal
power, or if the on-line exciter experiences a fault, the controller will auto-
matically switch to the backup drive chain (if available). Manual mode
could be used if an exciter or driver has been removed for service or for
any application where an automatic switch to the alternate drive chain is
not desired.
2.
Exciter A/B - These buttons select operational exciter. To use these
buttons, place the Auto/Manual button to Manual, then press the A or B
button to select the on-air drive chain.
d.
Pre-Driver/IPA Control box (located at the bottom of the screen on the right).
This dual driver has 2 switches:
1.
Auto/Manual - This toggle button should always be in the Auto position for
normal operation. Placing it in Manual mode prevents an autoswitch to the
alternate IPA (Preamp/Driver). In AUTO mode, if the on-air predriver/IPA-
drops below 50% of nominal power, the controller will automatically
switch to the backup pre-driver/IPA. Manual mode could be used if a
exciter or driver has been removed for service or for any application where
an automatic switch to the alternate IPA(Preamp/Driver) chain is not
desired.
2.
Pre-driver/IPA A/B - These are the manual selection buttons. To use these
buttons, place the Auto/Manual button to Manual, then press A or B to
activate the on-air predriver/IPA combination.
3.5.1
Drive Chain Faults
When the "Faults" button in Figure 3-5 is pressed, it will bring up the screen shown in
Figure 3-6. This screen is basically a fault display for exciters and pre-driver/IPA’s. For
more information on these faults and what to do if one should occur, refer to the M2X
exciter manual.
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...