6-10
888-2629-200
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 6 Diagnostics
Maxiva ULX COFDM Series
Table 6-4 Output Faults List
TYPE
Description
Fault Level or
Threshold
Transmitter
Action
Three
Strike
Available
in Life
Support
Cabinet
VSWR
(Reflected
Power Fault)
Cabinet
Reflected Power
has exceeded
10% of rated
power
Trip point is set at
VSWR = 1.9:1. Trip
point adjustable by
epot
RF MUTE, Fault
OFF after 3-
strike. The Time
interval between
strikes should be
about 3 seconds
YES
YES
System
VSWR
(Reflected
Power Fault)
System Reflected
Power has
exceeded 10% of
rated power
Trip point is set at
VSWR = 1.9:1
(Foldback starts at
1.4:1). Trip point
adjustable by epot.
Foldback set point
adjustable by soft-
ware
RF MUTE, Fault
OFF after 3-
strike. The Time
interval between
strikes should be
about 3 senconds
YES
YES for trip
NO for Fold-
back. Fold-
back routine
requires
PCM action
Cabinet For-
ward Power
Fault (Visual
Power in
Analog TV)
Cabinet Forward
Power has
exceeded 10% of
rated power
WARNING
NO
YES
YES
Cabinet
Aural Power
Fault (Ana-
log TV only)
Aural Power is
below 50% of
rated power
WARNING
NO
NO
NO
System For-
ward Power
Fault
System Forward
Power has
exceeded 10% of
rated power
WARNING
NO
YES
YES
System Aural
Power Fault
(Analog TV
only)
Aural Power is
below 50% of
rated power
WARNING
NO
NO
NO
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...