WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Maxiva ULX COFDM Series
NOTE:
Always be sure that you are accessing the desired cabinet number. The cabinet
being viewed is indicated in the upper left corner of the screen.
To get detailed information on a particular PA Module, press the Faults button on the
right section of the screen. The Faults button will take you to the PA Faults screen
shown in Figure 3-9.
3.6.1
PA Faults
This screen is basically a list of all faults monitored in each PA Module.
•
An active fault will be highlighted in RED
•
A warning condition will be highlighted in YELLOW.
The PA Faults screen in Figure 3-9, shows that PA Module #1, in PA Cabinet #1 has no
faults and 1 temperature warning. It also shows a power supply fault on module 3 and
an input power warning on module 4.
NOTE:
For a detailed explanation of all PA Faults in Figure 3-9 refer to Section 6, Diag-
nostics.
Figure 3-9 PA Faults Screen (PA Module 1 Selected)
PA Modules will fault off at 200W reflected power. Also, it will display a temperature
fault at 65° C ambient temperature (measured by a thermistor on the monitor board) or
90° C pallet temperature.
To Figure 3-8
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...