5-24
888-2629-200
10/6/10
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Maxiva ULX COFDM Series
STEP 6
Restore transmitter to normal operating condition and reset the
exciter output power to 100 mW.
STEP 7
End of procedure.
5.8.5.2
Cabinet Reject Load Thresholds
Cabinet reject loads should be set to approximately 3V thresholds at 100% reject power
levels.
5.8.5.3
System Reflected Thresholds
System reflected threshold voltage should be set to approximately 100 mV less than the
detector voltage level noted in "5.8.2.1 Calibrate Reflected Total Power" on page 5-19.
Approximately 2.4V is typical. For a 6kW digital transmitter this corresponds to a
reflected power level of 168W.
5.8.5.4
System Foldback Power
System foldback power (Watts) can be set as needed to a maximum value of 2.8% of
nominal output power.
5.8.5.5
FWD Pwr Warn
Sets kW level where power bar turns yellow.
5.8.5.6
Fwd Pwr Flt
Sets kW level where power bar turns red and fault is entered into log.
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...