10/6/10
888-2629-200
2-47
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation
Maxiva ULX COFDM Series
PERATURE. DO NOT TOUCH THE MODULES WITH BARE HANDS AFTER THE
TRANSMITTER HAS BEEN RUNNING. SPECIAL GLOVES CAN BE OBTAINED FROM
HARRIS, PART #0990006483 OR GRAINGER ITEM #4JF36. PRIOR TO MODULE
REMOVAL TURN OFF THE PA MODULE CIRCUIT BREAKER IN THE REAR OF THE
CABINET AND THEN ALLOW THE MODULE TO COOL FOR 30 SECONDS BEFORE
REMOVAL FROM THE RACK.
STEP 6
Verify all drain and vent valves are closed and make sure all coolant
system globe, gate and ball valves in the cooling loop are open before
proceeding with the initial turn on
.
STEP 7
Verify that the static pressure of the liquid cooling system is at 10
psig before the initial turn on.
Check the sight tube to verify the
coolant level and lack of air bubbles.
NOTE:
Each PA module that is installed may introduce air into the system. The system
will likely need to be recharged after modules are installed. The site glass should
be checked for fluid level and for air bubbles prior to turning on the transmitter
RF. Low coolant level or bubbles in the sight glass indicate that the cooling sys-
tem needs to be recharged.
2.13 Initial Turn-On
Read and understand the entire initial turn-on procedure before starting. Detailed use of
all GUI screens is given in.
STEP 1
Insure that the 3 phase AC mains has been connected to the
transmitter and cooling system.
Be ready to quickly disconnect the
power if necessary.
STEP 2
Engage the primary AC breaker switch(es) CB23 & CB24 on the AC
Mains Input Assembly at the rear of each transmitter cabinet.
STEP 3
Turn on the Control circuit breakers CB19 and CB20.
The Control
breakers are located at the cabinet rear, on the AC Mains Input
Assembly A15. This will activate the TCU power supplies, fans, and
predrivers.
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...