10/6/10
888-2629-200
5-23
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Maxiva ULX COFDM Series
Figure 5-11 Threshold Setting Screen
5.8.5.1
Exciter A & B Threshold Settings
Exciter A and B detector levels should be approximately 2.7V. This assumes a 100mW
(average) out.
Exciter A and B threshold levels can be set using the following steps:
STEP 1
Set the exciter to nominal output 100 mW (average).
STEP 2
Lower exciter output power to 50 mW (using the web browser)
.
STEP 3
Press the threshold Cal window and adjust the Cal value higher in
.1 V increments until the red fault LED on the TCU exciter switcher
card lights.
NOTE:
To view the LED on the exciter switcher card the front panel of the TCU must be
pivoted downward.
STEP 4
Lower the threshold Cal window value in .05 V increments until the
red LED on the exciter switcher card goes out.
STEP 5
Press done to accept this level
.
Summary of Contents for Maxiva ULX
Page 2: ...ii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 4: ...iv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 6: ...MRH 2 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 8: ...viii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 9: ...10 6 10 888 2629 200 ix WARNING Disconnect primary power prior to servicing ...
Page 10: ...x 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 12: ...xii 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 14: ...xiv 888 2629 200 10 6 10 WARNING Disconnect primary power prior to servicing ...
Page 18: ...Table of Contents Continued 4 ...