88
03-147015-00-00.fm
Operation
Manual regeneration
The manual regeneration must be started by the operator. This mode is
used for increased soot concentration.
The diesel particulate filter (regeneration required) information symbol
appears in the multifunction display.
•
Use the turn-push knob
to switch from the normal view to
the configuration menu and call up the diesel particulate filter menu.
•
The following conditions must be fulfilled for regeneration:
•
The parking brake has been applied
•
The engine is switched on and transport mode has been selected
•
Temperature > 10 °C
•
Regeneration lock has been switched off
•
If all the conditions have been fulfilled, the symbols
light up
green. The regeneration can be started. Use the turn-push knob to
select the START symbol
.
During regeneration, the progress is indicated by a yellow bar. If the
exhaust gas temperatures rise, the diesel particulate filter (hot exhaust
gases) information symbol
appears. A green bar is displayed
once regeneration has been completed.
•
Use the turn-push knob to select the EXIT symbol and switch back to
the normal view.
Fig. 91:
A
B
C
D
Note
For uninterrupted manual regeneration, note the following:
•
Do not change the speed
•
Leave the accelerator pedals in neutral position
•
Do not release the parking brake
•
Do not use the vehicle during manual regeneration
Non-observance leads to premature termination of
regeneration.
Summary of Contents for Citymaster 650
Page 23: ...01 147015 00 00 fm 23 Safety Instructions G A B D E F Fig 3 C F E C D G A A B H H C...
Page 27: ...02 147015 00 00 fm 27 Use Fig 5 24 19 25 23 22 21 20 16 18 17 10 26...
Page 31: ...02 147015 00 00 fm 31 Use Fig 7 63 64 66 65 62 68 67 56 51 52 55 54 53 59 58 60 61 57...
Page 33: ...02 147015 00 00 fm 33 Use Fig 8 74 69 76 70 72 71 77 78 79 80 81 73 75 82...
Page 97: ...04 147015 00 00 fm 97 Technical data 4 Technical data Fig 96 1270 982 3326 2269 866 1074 1200...